Supra R3 Motorscope — Advanced Three‑Phase Motor Protection with Wi‑Fi and Automation
Key Benefits
-
Robust motor protection with comprehensive safety features — overload, under-load, over- & under-voltage, phase failure, sequence anomalies, phase imbalance, and frequent‑start safeguards.
-
Wide coverage — supports three-phase motor nominal current from 1A to 140A [with the default 250:1 supplied CT or up to 600A with a 1000:1 CT (special order by contacting us) and frequencies from 40–70 Hz.
-
Compact and lightweight — only ~296 g, ideal for DIN-rail or space‑constrained installations
Standout Features
-
Built‑in Wi‑Fi connectivity for seamless remote monitoring, control, and reporting via a web interface or the NCS Toolbox app.
- Optional Ethernet Connector for robust network connectivity in industrial applications.
- Optional Earth Leakage Detection for safe operations at 400V / 525V / 1000V by checking the motor leads for possible earth faults BEFORE the motor starts AND while the motor is RUNNING.
-
Up to eight programmable scheduler timers, capable of offline operation even during network disruptions.
-
Remote ON/OFF control streamlines operations and reduces manual intervention.
-
Under‑load recovery timer, auxiliary inhibit input, reset interface, alarm relay, and built‑in real‑time clock enhance automation and fault response.
Technical Specifications
-
Motor Voltage: Three-phase 400 V / 525 V / 1000 V
- Control Voltage: 400VAC (on the Supra-R3A model), 90 – 240VAC (on the Supra-R3B and Supra-R3C models)
-
Current Range: 1A to 140A (with default 250:1 CT or up to 600A with a custom 1000:1 CT)
-
Frequency: 40–70 Hz
-
Relay Rating: 400 V, 8 A
-
Power Consumption: Approx. 3 VA
-
Cos ϕ Range: 0.2 – 1 (inductive)
-
Operating Temperature: -15 °C to +70 °C
-
Dimensions: Compact form factor; weight ~296 g
How It Works
-
During first‑time setup, the unit is calibrated while the motor runs under normal conditions. This defines the motor’s safe operating envelope. Continuous monitoring ensures the motor remains within those set thresholds.
-
If any unsafe condition arises (e.g. voltage spikes, overload), the Supra R3 takes immediate action to protect the motor system from damage.
-
Collected data from up to 43 recent motor stops can be retrieved via optimizer logging and used for diagnostics or maintenance planning.
Use Cases
-
Ideal for industrial motors, pump control, borehole installations, and process applications where uptime and reliability are critical.
-
Suited to remote or distributed systems thanks to built‑in Wi‑Fi or Ethernet connector and offline scheduler operation.






Reviews